Graphene-Based Thermopile for Thermal Imaging Applications.

Hsu, Allen L; Herring, Patrick K; Gabor, Nathaniel M; Ha, Sungjae; Shin, Yong Cheol; Song, Yi; Chin, Matthew; Dubey, Madan et al. · Nano Lett · 2015

basic_science · Level V

Where this comes from

Abstract

In this work, we leverage graphene's unique tunable Seebeck coefficient for the demonstration of a graphene-based thermal imaging system. By integrating graphene based photothermo-electric detectors with micromachined silicon nitride membranes, we are able to achieve room temperature responsivities on the order of ~7-9 V/W (at λ = 10.6 μm), with a time constant of ~23 ms. The large responsivities, due to the combination of thermal isolation and broadband infrared absorption from the underlying SiN membrane, have enabled detection as well as stand-off imaging of an incoherent blackbody target (300-500 K). By comparing the fundamental achievable performance of these graphene-based thermopiles with standard thermocouple materials, we extrapolate that graphene's high carrier mobility can enable improved performances with respect to two main figures of merit for infrared detectors: detectivity (>8 × 10(8) cm Hz(1/2) W(-1)) and noise equivalent temperature difference (<100 mK). Furthermore, even average graphene carrier mobility (<1000 cm(2) V(-1) s(-1)) is still sufficient to detect the emitted thermal radiation from a human target.