MIRD Pamphlet No. 26: Joint EANM/MIRD Guidelines for Quantitative 177Lu SPECT Applied for Dosimetry of Radiopharmaceutical Therapy.
Where this comes from
- Record sourced from PubMed, PMID 26471692.
- Also identified by DOI 10.2967/jnumed.115.159012.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The accuracy of absorbed dose calculations in personalized internal radionuclide therapy is directly related to the accuracy of the activity (or activity concentration) estimates obtained at each of the imaging time points. MIRD Pamphlet no. 23 presented a general overview of methods that are required for quantitative SPECT imaging. The present document is next in a series of isotope-specific guidelines and recommendations that follow the general information that was provided in MIRD 23. This paper focuses on (177)Lu (lutetium) and its application in radiopharmaceutical therapy.
Medical subject headings
- Lutetium
- Radioisotopes
- Radiopharmaceuticals
- Tomography, Emission-Computed, Single-Photon