Outcomes of Repeat Boston Type 1 Keratoprosthesis Implantation.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 26482467.
- Also identified by DOI 10.1016/j.ajo.2015.10.012.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To describe the outcomes and prognostic characteristics of patients who had a repeat Boston type 1 keratoprosthesis (KPro) implantation. Retrospective case series. setting: Data regarding preoperative clinical and demographic characteristics and postoperative course during initial and repeat KPro placement were collected at multiple centers across the country. Forty-eight eyes underwent explantation of KPro owing to complications between September 2003 and August 2014 at 5 participating tertiary eye care centers in the United States. Of those, 36 eyes that received a subsequent replacement device were included. Visual acuity (VA) outcomes and postoperative complications. Ocular surface disease was significantly more common in eyes that required a device explantation, compared to those that retained the device (P < .001). Sixty-seven percent of eyes (24/36) achieved VA ≥ 20/200 vision after the repeat KPro. The probability of these 24 eyes maintaining VA ≥ 20/200 after the repeat KPro was 87% at 1 year and 75% at 2 years. Predictors of the ability to maintain vision ≥ 20/200 following surgery were a better last-recorded vision before explantation (P = .0002) and better vision immediately after repeat KPro (P < .001). Ocular surface disease and its complications were associated with more frequent device removal. In these patients, repeat KPro resulted in restoration of vision. A reasonable visual acuity prior to device removal was associated with favorable long-term postoperative visual acuity and retention.
Medical subject headings
- Artificial Organs
- Device Removal
- Postoperative Complications
- Prosthesis Implantation