Quantitative Comparison of Misregistration in Abdominal and Pelvic Organs Between PET/MRI and PET/CT: Effect of Mode of Acquisition and Type of Sequence on Different Organs.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 26587937.
- Also identified by DOI 10.2214/AJR.15.14450.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective of our study was to quantitatively compare misregistration in selected abdominopelvic organs between PET/CT acquisitions and simultaneous and sequential PET/MRI acquisitions. PET/MR images of 15 healthy volunteers and seven patients with bladder cancer were acquired. Ten clinical PET/CT studies acquired during the same time frame of body mass index-matched control subjects were chosen. PET/MRI and PET/CT registration of selected abdominopelvic organs was measured and compared. The overall mean misregistration with PET/MRI was significantly higher than that with PET/CT (p < 0.001). Sequential PET/MRI acquisition was significantly inferior to PET/CT (p = 0.02), whereas there was no significant difference between simultaneous PET/MRI acquisition and PET/CT (p = 0.38). Simultaneous PET/MRI acquisition was significantly better than sequential PET/MRI acquisition (p < 0.001). The mean misregistration for all organs with the T1-weighted volumetric interpolated breath-hold examination (VIBE) sequence (2.39 cm) was significantly inferior to PET/CT (p < 0.001). Although the T2-weighted HASTE breath-hold sequence was significantly inferior to PET/CT (p = 0.04), the T2 HASTE non-breath-hold sequence and T2 STIR sequence (0.18 cm) were significantly superior to both PET/CT and the T1 VIBE sequence (p < 0.001). Within the same sequence (T1 VIBE breath-hold sequence), the mean misregistrations with sequential and simultaneous PET/MRI acquisitions were both significantly greater than with PET/CT (p < 0.001), whereas simultaneous PET/MRI acquisition was superior to sequential PET/MRI acquisition (p < 0.001). In the abdominopelvic organs, sequentially obtained PET/MRI data have significantly higher misregistration than both PET/CT data and simultaneously acquired PET/MRI data. Simultaneously obtained PET/MRI data are statistically noninferior to PET/CT. Nonradial T1 VIBE has the highest misregistration, whereas T2 STIR and T2 HASTE non-breath-hold are significantly better than both PET/CT and T1 VIBE.
Medical subject headings
- Abdomen
- Multimodal Imaging
- Urinary Bladder Neoplasms