Contact Lens-Assisted Pull-Through Technique for Delivery of Tri-Folded (Endothelium in) DMEK Grafts Minimizes Surgical Time and Cell Loss.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 26686969.
- Also identified by DOI 10.1016/j.ophtha.2015.10.050.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the feasibility and outcomes of contact lens-assisted bimanual pull-through delivery of Descemet membrane endothelial keratoplasty (DMEK) tissue trifolded with the endothelium inward. Prospective, noncomparative, interventional case series. Forty-two consecutive eyes of 42 patients with Fuchs endothelial dystrophy with or without cataract. Standardized DMEK was performed as a single procedure (n = 9) or in combination with phacoemulsification and implantation of a posterior chamber intraocular lens (n = 33) using prestripped donor tissue punched to a diameter of 8.25 mm and then trifolded with the endothelium in. Using a sterile soft contact lens as scaffold, the tissue was loaded in this configuration into a disposable cartridge and delivered into the anterior chamber under continuous irrigation using a bimanual pull-through technique to facilitate spontaneous proper unfolding. Surgical time, intraoperative and postoperative complications, visual acuity 3 and 6 months after surgery, and endothelial cell loss 6 months after surgery. Surgery was uneventful in all cases and the time required for the DMEK procedure (from Descemet scoring until final air filling) never exceeded 20 minutes (average, 17.1±1.6 minutes). The only complication observed after surgery was graft detachment (10 of 42 eyes [23.8%]), successfully managed in all cases by single rebubbling within 6 days from surgery. In all eyes with a minimum postoperative follow-up of 6 months (n = 20), best spectacle-corrected visual acuity was 20/25 or better and the average endothelial cell density (±standard deviation) was 2363.8±82.7 cells/mm(2) (range, 2258-2490 cells/mm(2)). The cell loss calculated as a percentage of the preoperative value determined at the eye bank (range, 2500-2700 cells/mm(2)) was 9.9±2.1% (range, 4.1%-11.9%). Delivering DMEK tissue, trifolded with the endothelium inward, reduces surgical trauma to donor cells and facilitates spontaneous unfolding, thus minimizing surgical time.
Medical subject headings
- Contact Lenses
- Descemet Stripping Endothelial Keratoplasty
- Fuchs' Endothelial Dystrophy
- Tissue Scaffolds