Accuracy of computer-assisted iliosacral screw placement using a hybrid operating room.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 26708797.
- Also identified by DOI 10.1016/j.injury.2015.11.023.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In recent years hybrid operating rooms were established all over the world. In our setting we combined a 3D flat-panel c-arm (Artis zeego, Siemens) with a navigation system (BrainLab curve, BrainLab). This worldwide unique combination enables the surgeon to visualise an entire pelvis in CT-like image quality with a single 3D-scan. The aim of our study was to investigate, if utilisation of a hybrid operating room increases the accuracy of SI-screws in comparison to standard 3D-navigation. Retrospective, not randomised single centre case series at a level I trauma centre. Inclusion criterion was insertion of a percutaneous iliosacral screw using image-guidance in the hybrid operating room. 61 patients (35 female, 26 male) were included from June 2012 till October 2014. 65 iliosacral screws were inserted. Intraoperative 3D-scans and postoperative scans were examined to investigate screw placement. The results were compared to a preceding study performed in 2012 using conventional 3D-navigation. Statistical calculations were performed with Microsoft Excel 2011 and SPSS. 65 iliosacral screws were implanted. Two different types of screws were implanted: 1. "Standard" iliosacral screws stabilizing one joint/a unilateral fracture. 2. Single SI-screws stabilizing both SI-joints and if present a bilateral fracture. Forty one patients were included in group 1 (screws n=45). There was no perforation in 43 screws, grade 1 perforation in 2 screws. There was no grade 2 or 3 perforation in this group. Compared to the conventional 3D-navigated screws there was a highly significant difference (p<0.001). Twenty patients could be included in group 2. Eleven screws showed a complete intraosseous position. There was grade 1 perforation in 2 screws, grade 2 perforation in 5 screws and grade 3 perforation in 2 screws. Improvements in image quality and enlargement of the display window lead to better intraoperative visualisation of the entire dorsal pelvis. Thereby the accuracy of computer-assisted iliosacral screws could be increased using a hybrid operating room. Furthermore difficult tasks like a single screw for both joints can be accomplished.
Medical subject headings
- Bone Screws
- Fluoroscopy
- Fracture Fixation, Internal
- Fractures, Bone
- Imaging, Three-Dimensional
- Operating Rooms
- Pelvic Bones
- Sacroiliac Joint
- Surgery, Computer-Assisted