Compliance with the proper use of an individual radiation dosimeter among children and the effects of improper use on the measured dose: a retrospective study 18-20 months following Japan's 2011 Fukushima nuclear incident.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 26719319.
- Also identified by DOI 10.1136/bmjopen-2015-009555 and PMC identifier 4710822.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To identify profiles of children who did not properly use individual radiation dosimeters following Japan's 2011 Fukushima nuclear incident, and to assess how much error is generated by improper dosimeter use. The participants in this study comprised 1637 school children who participated in the external radiation exposure screening programme administrated by Minamisoma City (located 20-30 km from the Fukushima nuclear plant) between 18 and 20 months after the Fukushima incident. We assessed the factors associated with improper use (non-use) of the dosimeters at specific time periods during the day (school commuting hours, at school, at home, outdoors and at bedtime) using logistic regression analyses. Ratios of the measured dose to regression estimates of the 'expected' dose (referred to as an error due to non-use) were also examined. Only 119 children (7.3%) used the dosimeters properly in all time periods. This low rate was attributed primarily to non-use when children were in the home and outdoors, rather than at school. School level, air dose rate at home, gender, membership in outdoor sports clubs and time spent outdoors on weekends, were significantly associated with improper use, after adjustment for covariates. Data from children who did not wear the dosimeters to school and outdoors had statistically significant (but clinically insignificant) errors (ratio: 1.13, p<0.01; and 0.97, p<0.05, respectively), whereas improper use of the dosimeters at school, at home and at bedtime did not generate significant errors. Well-targeted rigorous instructions on the use of the dosimeter are required, with particular focus on time periods other than school hours. However, given the small dose error due to the improper use of the dosimeters, even if the dosimeters are improperly used, solid evaluation of the radiation exposure may be possible with some accuracy.
Medical subject headings
- Film Dosimetry
- Fukushima Nuclear Accident
- Patient Compliance
- Students