Recurrent atraumatic anterior hip dislocation: Treated by dual mobility system.

Xu, Jie X; Meyerkort, Daniel; Khan, Riaz J · J Orthop · 2015

case_report · Level V

Where this comes from

Abstract

To highlight a case of recurrent atraumatic anterior hip dislocation management using a dual mobility prothesis. The stability of the patient's hip was assessed using X-ray and MRI scans. Upon the third spontaneous anterior dislocation it was decided with the patient's consent to undergo a total hip replacement. A piriformis sparing anterior approach was use with the insertion of a dual mobility bearing. This consisted of an uncemented porous titanium cup articulating with a 28 mm head in a 42 mm mobile polyethylene liner. Mobilising pain free at 6 weeks post operation with no further dislocations at 6 months follow up. Dual mobility hip replacements was used successfully in our patient with recurrent atraumatic anterior hip dislocation.

Anatomy