Comparative Performance of ¹⁸F-FDG PET/MRI and ¹⁸F-FDG PET/CT in Detection and Characterization of Pulmonary Lesions in 121 Oncologic Patients.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 26742715.
- Also identified by DOI 10.2967/jnumed.115.167486.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Our objective was to compare (18)F-FDG PET/MRI (performed using a contrast-enhanced T1-weighted fat-suppressed volume-interpolated breath-hold examination [VIBE]) with (18)F-FDG PET/CT for detecting and characterizing lung lesions in oncologic patients. In 121 oncologic patients with 241 lung lesions, PET/MRI was performed after PET/CT in a single-injection protocol (260 ± 58 MBq of (18)F-FDG). The detection rates were computed for MRI, the PET component of PET/CT, and the PET component of PET/MRI in relation to the CT component of PET/CT. Wilcoxon testing was used to assess differences in lesion contrast (4-point scale) and size between morphologic datasets and differences in image quality (4-point scale), SUVmean, SUVmax, and characterization (benign/malignant) between PET/MRI and PET/CT. Correlation was determined using the Pearson coefficient (r) for SUV and size and the Spearman rank coefficient (ρ) for contrast. The detection rates for MRI, the PET component of PET/CT, and the PET component of PET/MRI were 66.8%, 42.7%, and 42.3%, respectively. There was a strong correlation in size (r= 0.98) and SUV (r= 0.91) and a moderate correlation in contrast (ρ = 0.48). Image quality was better for PET/CT than for PET/MRI (P< 0.001). Lesion measurements were smaller for MRI than for CT (P< 0.001). SUVmax and SUVmean were significantly higher for PET/MRI than for PET/CT (P< 0.001 each). There was no significant difference in lesion contrast (P= 0.11) or characterization (P= 0.076). In the detection and characterization of lung lesions 10 mm or larger, (18)F-FDG PET/MRI and (18)F-FDG PET/CT perform comparably. Lesion size, SUV and characterization correlate strongly between the two modalities. However, the overall detection rate of PET/MRI remains inferior to that of PET/CT because of the limited ability of MRI to detect lesions smaller than 10 mm. Thus, thoracic staging with PET/MRI bears a risk of missing small lung metastases.
Medical subject headings
- Fluorodeoxyglucose F18
- Lung Neoplasms
- Magnetic Resonance Imaging
- Positron-Emission Tomography
- Radiopharmaceuticals