The Use of Oxidized Regenerated Cellulose for Video-Assisted Thoracic Surgery.
Where this comes from
- Record sourced from PubMed, PMID 26777946.
- Also identified by DOI 10.1016/j.athoracsur.2015.08.078.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Disturbance of the surgical view during video-assisted thoracic surgery (VATS) as a result of blood oozing from the wound surface of the access port may lead to additional stress on surgeons and is difficult to prevent. We used a wound edge protector with oxidized regenerated cellulose (ORC) rings for the wound surfaces of the access ports and eliminated the problem. Furthermore, no hemostatic procedure was required for the wound surface before wound closure because the ORC rings completely stopped wound surface bleeding during the operation. ORC rings enhanced protection of the thoracoscopic port and the quality of VATS.
Medical subject headings
- Cellulose, Oxidized
- Hemostatics
- Thoracic Surgery, Video-Assisted