Automated Quantification of Capillary Nonperfusion Using Optical Coherence Tomography Angiography in Diabetic Retinopathy.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 26795548.
- Also identified by DOI 10.1001/jamaophthalmol.2015.5658 and PMC identifier 4978127.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Macular ischemia is a key feature of diabetic retinopathy (DR). Quantification of macular ischemia has potential as a biomarker for DR. To assess the feasibility of automated quantification of capillary nonperfusion as a potential sign of macular ischemia using optical coherence tomography (OCT) angiography. An observational study conducted in a tertiary, subspecialty, academic practice evaluated macular nonperfusion with 6 × 6-mm OCT angiography obtained with commercially available 70-kHz OCT and fluorescein angiography (FA). The study was conducted from January 22 to September 18, 2014. Data analysis was performed from October 1, 2014, to April 7, 2015. Participants included 12 individuals with normal vision serving as controls and 12 patients with various levels of DR. Preplanned primary measures were parafoveal and perifoveal vessel density, total avascular area, and foveal avascular zone as detected with 6 × 6-mm OCT angiography and analyzed using an automated algorithm. Secondary measures included the agreement of the avascular area between the OCT angiogram and FA. Compared with the 12 healthy controls (11 women; mean [SD] age, 54.2 [14.2] years), the 12 participants with DR (4 women; mean [SD] age, 55.1 [12.1] years) had reduced parafoveal and perifoveal vessel density by 12.6% (95% CI, 7.7%-17.5%; P < .001) and 10.4% (95% CI, 6.8%-14.1%; P < .001), respectively. Total avascular area and foveal avascular zone area were greater in eyes with DR by 0.82 mm2 (95% CI, 0.65-0.99 mm2; P = .02) and 0.16 mm2 (95% CI, 0.05-0.28 mm2; P < .001). The agreement between the vascular areas in the OCT angiogram and FA had a κ value of 0.45 (95% CI, 0.21-0.70; P < .001). Total avascular area in the central 5.5-mm-diameter area distinguished eyes with DR from control eyes with 100% sensitivity and specificity. Avascular area analysis with an automated algorithm using OCT angiography, although not equivalent to FA, detected DR reliably in this small pilot study. Further study is necessary to determine the usefulness of the automated quantification in clinical practice.
Medical subject headings
- Automation
- Diabetic Retinopathy
- Fluorescein Angiography
- Ischemia
- Retinal Vessels
- Tomography, Optical Coherence