Radiation safety for anaesthesia providers in the orthopaedic operating room.
systematic_review · Level I
Where this comes from
- Record sourced from PubMed, PMID 26874074.
- Also identified by DOI 10.1111/anae.13400.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In many orthopaedic operating rooms, anaesthesia providers routinely wear lead aprons for protection from radiation, but some studies have questioned whether this is needed. We conducted a systematic review to identify studies that measured the amount of radiation that anaesthetists were exposed to in the orthopaedic operating room. Multiple studies have shown that at 1.5 m from the source of radiation, anaesthetists received no radiation, or amounts so small that a person would have to be present in an unreasonable number of operations to receive cumulative doses of any significance. Radiation doses at this distance were often at the limits of the sensitivity of the measuring dosimeter. We question the need to wear lead protection for anaesthesia providers who are routinely at 1.5 m or a greater distance from standard fluoroscopy units.
Medical subject headings
- Anesthesia
- Occupational Exposure
- Operating Rooms
- Orthopedics
- Protective Clothing
- Radiation Protection