Ventricular Septal Perforation Caused by the Strut of a Mitral Valve Bioprosthesis.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 26897197.
- Also identified by DOI 10.1016/j.athoracsur.2015.05.035.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Ventricular rupture is a well-known complication of mitral valve replacement. We report a rare complication in which the strut of a recently implanted mitral bioprosthesis eroded through the ventricular septum. We present the strategy of the reoperation in which the sutures holding the repair patch were also used to support the new prosthesis. In addition to ventricular rupture and obstruction of the left ventricular outflow tract by a mitral bioprosthesis, the risk of iatrogenic ventricular septal defect (VSD) should be considered when choosing, sizing, and implanting a mitral bioprosthesis.
Medical subject headings
- Bioprosthesis
- Heart Valve Prosthesis Implantation
- Iatrogenic Disease
- Mitral Valve Insufficiency
- Ventricular Septal Rupture