Introduction of a New Locking Nail for Treatment of Intraarticular Calcaneal Fractures.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 26901539.
- Also identified by DOI 10.1097/BOT.0000000000000482.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To reduce the complication rate associated with open reduction and internal fixation of displaced intraarticular calcaneal fractures through extensile approaches, a locking nail system (C-Nail) was developed for internal fixation. Prospective case-control study. Two level I trauma centers (university hospital) and 1 large regional hospital in the Czech Republic and Germany. One hundred three patients (89 male and 14 female; mean age, 45.6 years) with 106 calcaneal fractures were treated between February 2011 and October 2013. In all 106 cases, the stainless steel C-Nail with a length of 65 mm, a diameter of 8 mm, and 7 locking options was used for internal fixation. Previous reduction of the posterior facet was performed in 15 cases percutaneously, assisted by arthroscopy and fluoroscopy, and in 91 cases by a sinus tarsi approach. The reduced joint surface was fixed by 1 or 2 compression screws. All other fragments were fixed after reduction and temporary K-wire fixation with the C-Nail introduced percutaneously through the tuberosity and 5 to 6 interlocking screws. The latter were introduced into the sustentacular, the tuberosity, and the anterior process fragments with an aiming device consisting of 3 arms. Patients were assessed for complications, restoration of Böhler angle, posterior facet reduction with postoperative computed tomography, and weight-bearing radiographs at 6 months. Functional outcome was assessed using the American Orthopaedic Foot & Ankle Society (AOFAS) ankle/hindfoot scale after 6 and 12 months for all patients. Wound edge necrosis was seen in 2 cases (1.9%), and soft tissue infection was observed in 1 case (0.9%). Böhler angle improved from 7.3 degree preoperatively to 28.7 degree at 6 months. The posterior facet step-off was reduced from 5.3 mm preoperatively to 0.7 mm postoperatively. The average AOFAS score averaged 89.5 at 6-month and 92.6 at 12-month follow-up. The C-Nail is a new locking system for treatment of displaced intraarticular calcaneal fractures combining a primary stability with reduced soft tissue complications. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Medical subject headings
- Ankle Fractures
- Bone Nails
- Calcaneus
- Fracture Fixation, Internal
- Intra-Articular Fractures
Anatomy
- ankle
- foot