Comparison of diffusion tensor imaging and <sup>11</sup>C-methionine positron emission tomography for reliable prediction of tumor cell density in gliomas.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 26918477.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
OBJECTIVE Diffusion MRI is attracting increasing interest for tissue characterization of gliomas, especially after the introduction of antiangiogenic therapy to treat malignant gliomas. The goal of the current study is to elucidate the actual magnitude of the correlation between diffusion MRI and cell density within the tissue. The obtained results were further extended and compared with metabolic imaging with <sup>11</sup>C-methionine (MET) PET. METHODS Ninety-eight tissue samples from 37 patients were stereotactically obtained via an intraoperative neuronavigation system. Diffusion tensor imaging (DTI) and MET PET were performed as routine presurgical imaging studies for these patients. DTI was converted into fractional anisotropy (FA) and apparent diffusion coefficient (ADC) maps, and MET PET images were registered to Gd-administered T1-weighted images that were used for navigation. Metrics of FA, ADC, and tumor-to-normal tissue ratio of MET PET along with relative values of FA (rFA) and ADC (rADC) compared with normal-appearing white matter were correlated with cell density of the stereotactically obtained tissues. RESULTS rADC was significantly lower in lesions obtained from Gd-enhancing lesions than from nonenhancing lesions. Although rADC showed a moderate but statistically significant negative correlation with cell density (p = 0.010), MET PET showed a superb positive correlation with cell density (p < 0.0001). On the other hand, rFA showed little correlation with cell density. CONCLUSIONS The presented data validated the use of rADC for estimating the treatment response of gliomas but also caution against overestimating its limited accuracy compared with MET PET.
Medical subject headings
- Brain Neoplasms
- Diffusion Tensor Imaging
- Glioma
- Methionine
- Positron-Emission Tomography
- Radiopharmaceuticals