Volar locking plate fixation for distal radius fractures: Does age affect outcome?

Ezzat, Ahmed; Baliga, Santosh; Carnegie, Carol; Johnstone, Alan · J Orthop · 2016

prospective_cohort · Level II

Where this comes from

Abstract

The AAOS guidelines are unable to recommend for or against operative treatment of distal radius fractures in older patients. This study compares the outcomes of older patients (≥60 years) against a cohort of younger patients treated with volar locking plate (VLP) fixation. We assessed 78 patients, comparing range of movement (ROM), grip and pinch strength, subjective Visual Analogue Score (VAS) for pain and function and composite outcome scores. There was no difference in clinical outcomes between the two groups at six months. Open reduction and VLP for distal radius fractures gives comparable outcomes in the older population.

Anatomy