The price of robustness; impact of worst-case optimization on organ-at-risk dose and complication probability in intensity-modulated proton therapy for oropharyngeal cancer patients.
other
Where this comes from
- Record sourced from PubMed, PMID 27178142.
- Also identified by DOI 10.1016/j.radonc.2016.04.038.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To quantify the impact of the degree of robustness against setup errors and range errors on organ-at-risk (OAR) dose and normal tissue complication probabilities (NTCPs) in intensity-modulated proton therapy for oropharyngeal cancer patients. For 20 oropharyngeal cases (10 unilateral and 10 bilateral), robust treatment plans were generated using 'minimax' worst-case optimization. We varied the robustness against setup errors ('setup robustness') from 1 to 7mm and the robustness against range errors ('range robustness') from 1% to 7% (+1mm). We evaluated OAR doses and NTCP-values for xerostomia, dysphagia and larynx edema. Varying the degree of setup robustness was found to have a considerably larger impact than varying the range robustness. Increasing setup robustness from 1mm to 3, 5, and 7mm resulted in average NTCP-values to increase by 1.9, 4.4 and 7.5 percentage point, whereas they increased by only 0.4, 0.8 and 1.2 percentage point when increasing range robustness from 1% to 3%, 5% and 7%. The degree of setup robustness was observed to have a clinically significant impact in bilateral cases in particular. For oropharyngeal cancer patients, minimizing setup errors should be given a higher priority than minimizing range errors.
Medical subject headings
- Organs at Risk
- Oropharyngeal Neoplasms
- Proton Therapy
- Radiation Injuries
- Radiotherapy, Intensity-Modulated