Neonatal Intensive Care Unit Quality Initiative: Identifying Preanalytical Variables Contributing to Specimen Hemolysis and Measuring the Impact of Evidence-Based Practice Interventions.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 27357290.
- Also identified by DOI 10.1093/ajcp/aqw086.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Blood specimen hemolysis is a major cause of sample recollection in the neonatal intensive care unit. We aimed to reduce the hemolysis rate from 6.3% at baseline to less than 4% within the 9 months' duration of the study. Intravenous infusion of lipid emulsion during sample collection, sample collection site, and blood sample transportation methods were investigated as possible contributors to hemolysis. Subsequently, two practice improvements were implemented: pausing lipid emulsion infusion prior to collection and slowing withdrawal rates through arterial catheters. Samples were more likely to be hemolyzed if they were collected during lipid infusion and subsequently transported by pneumatic tube or collected through an arterial catheter. Retrospective analysis demonstrated a decreased number of tests cancelled due to specimen hemolysis (3.5%) after our interventions. We identified three variables contributing to hemolysis and instituted two clinical practice interventions to significantly reduce test cancellations due to hemolysis.
Medical subject headings
- Blood Specimen Collection
- Hemolysis
- Intensive Care Units, Neonatal
- Quality Control
- Specimen Handling