Mechanical chest compression devices are associated with poor neurological survival in a statewide registry: A propensity score analysis.

Youngquist, Scott T; Ockerse, Patrick; Hartsell, Sydney; Stratford, Chris; Taillac, Peter · Resuscitation · 2016

retrospective_cohort · Level III

Where this comes from

Abstract

To compare functional survival (discharge cerebral performance category 1 or 2) among victims of out-of-hospital cardiac arrest (OHCA) who had resuscitations performed using mechanical chest compression (mech-CC) devices vs. those using manual chest compressions (man-CC). Observational cohort of 2600 cases of OHCA from a statewide, prospectively-collected cardiac arrest registry (Utah Cardiac Arrest Registry to Enhance Survival). Comparison of functional survival among those receiving mech-CC vs man-CC was performed using a mixed-effects Poisson model with inverse probability weighted propensity scores to control for selection bias. Overall, mech-CC was utilized in 405/2600 (16%) of the total arrests in Utah during this period. 371/405 (92%) were of the load-distributing band type (AutoPulse(®)) and 22/405 (5%) were mechanical piston devices (LUCAS™), while 12/405 (3%) employed other devices. The relative risk (RR) for functional survival comparing mech-CC to man-CC after propensity score adjustment was 0.41 (95% CI 0.24-0.70, p=0.001). Mechanical chest compression device use was associated with lower rates of functional survival in this propensity score analysis, controlling for Utstein variables and early return of spontaneous circulation.