Rapid delayed growth of ruptured supraclinoid blister aneurysm after successful flow diverting stent treatment.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 27471186.
- Also identified by DOI 10.1136/neurintsurg-2016-012506.rep.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A 62-year-old woman presented with a subarachnoid hemorrhage secondary to a ruptured right supraclinoid internal carotid artery blister aneurysm. She was treated in an emergent fashion with two flow diverting pipeline embolization devices (PED) deployed in a telescoping fashion. CT angiography performed for unrelated reasons at 7 months showed successful treatment of the aneurysm without evidence of residual aneurysm. However, a follow-up digital subtraction angiogram performed at 9 months showed a large aneurysm in a modified position compared with the original aneurysm. This is the first case of rapid regrowth of a supraclinoid blister aneurysm after successful treatment with a PED, and demonstrates the need for close follow-up for similar aneurysms treated with this novel device.
Medical subject headings
- Aneurysm, Ruptured
- Carotid Artery Diseases
- Carotid Artery, Internal
- Embolization, Therapeutic
- Stents