Deployment of a Reverse Transcription Loop-Mediated Isothermal Amplification Test for Ebola Virus Surveillance in Remote Areas in Guinea.

Kurosaki, Yohei; Magassouba, N'Faly; Bah, Hadja Aïssatou; Soropogui, Barré; Doré, Amadou; Kourouma, Fodé; Cherif, Mahamoud Sama; Keita, Sakoba et al. · J Infect Dis · 2016

other · Level V

Where this comes from

Abstract

To strengthen the laboratory diagnostic capacity for Ebola virus disease (EVD) in the remote areas of Guinea, we deployed a mobile field laboratory and implemented reverse transcription loop-mediated isothermal amplification (RT-LAMP) for postmortem testing. We tested 896 oral swab specimens and 21 serum samples, using both RT-LAMP and reverse transcription-polymerase chain reaction (RT-PCR). Neither test yielded a positive result, and the results from RT-LAMP and RT-PCR were consistent. More than 95% of the samples were tested within 2 days of sample collection. These results highlight the usefulness of the RT-LAMP assay as an EVD diagnostic testing method in the field or remote areas.

Medical subject headings