Revision of ceramic fracture with ceramic-on-polyethylene in total hip arthroplasty: Medium-term results.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 27507545.
- Also identified by DOI 10.1016/j.injury.2016.07.059.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
There is no consensus on the bearing of choice in revision for ceramic fracture after total hip arthroplasty (THA). The aim of this study was to evaluate the outcomes using ceramic-on-polyethylene (CoP) articulation in revision for ceramic breakage. Twelve patients who underwent revision hip surgery between 2002 and 2013 were followed-up. Appropriate surgical technique, including accurate synoviectomy, was used. The cup and the head were changed in four patients and only the liner and the head were replaced in the remaining eight patients. At the final follow-up there were no cases of re-revision due to tribological reasons, and only one case of polyethylene (PE) wear and osteolysis was scheduled for a new revision because of clear cup malposition. Complications were four cases of dislocation, one case of loosening and one case of infection. Revision of fractured ceramic is a challenging situation with a high risk of early complications. Using CoP liners with accurate synoviectomy and correction of misalignment can be considered a valuable bearing option at medium-term follow-up.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Fractures, Bone
- Hip Prosthesis
- Prosthesis Failure
- Reoperation