Construct validity of a novel assessment tool for ultrasound-guided axillary brachial plexus block.

Ahmed, O M A; O'Donnell, B D; Gallagher, A G; Breslin, D S; Nix, C M; Shorten, G D · Anaesthesia · 2016

prospective_cohort · Level II

Where this comes from

Abstract

The purpose of this study was to examine the construct validity and reliability of a novel metrics-based assessment tool, previously developed for ultrasound-guided axillary brachial plexus block. Five expert and eight novice anaesthetists performed a total of 18 ultrasound-guided axillary brachial plexus blocks on the same number of patients. A trained investigator video-taped procedures according to a pre-defined protocol. Two trained consultant anaesthetists independently scored the videos using the assessment tool. Compared with novices, experts completed more steps (mean 41.0 vs. 33.1, p = 0.001), had fewer procedural errors (2.8 vs. 7.9, p < 0.0001), had fewer critical errors (0.8 vs. 1.3, p = 0.030), and fewer total errors (3.5 vs. 9.1, p < 0.0001). The mean inter-rater reliability for scoring of experts' performance was 0.91, for novices' performance was 0.84, and for all performance combined (n = 18) was 0.88. This assessment tool is valid, and discriminates reliably between expert and novice performance for placement of ultrasound-guided axillary brachial plexus blocks.

Medical subject headings