Optimization of Carbon Ion Treatment Plans by Integrating Tissue Specific α/β-Values for Patients with Non-Resectable Pancreatic Cancer.
Where this comes from
- Record sourced from PubMed, PMID 27736917.
- Also identified by DOI 10.1371/journal.pone.0164473 and PMC identifier 5063341.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
BACKGROUND: The aim of the thesis is to improve treatment plans of carbon ion irradiation by integrating the tissues' specific [Formula: see text]-values for patients with locally advanced pancreatic cancer (LAPC). MATERIAL AND METHODS: Five patients with LAPC were included in this study. By the use of the treatment planning system Syngo RT Planning (Siemens, Erlangen, Germany) treatment plans with carbon ion beams have been created. Dose calculation was based on [Formula: see text]-values for both organs at risk (OAR) and the tumor. Twenty-five treatment plans and thirty-five forward calculations were created. With reference to the anatomy five field configurations were included. Single Beam Optimization (SBO) and Intensity Modulated Particle Therapy (IMPT) were used for optimization. The plans were analyzed with respect to both dose distributions and individual anatomy. The plans were evaluated using a customized index. RESULTS: With regard to the target, a field setup with one single posterior field achieves the highest score in our index. Field setups made up of three fields achieve good results in OAR sparing. Nevertheless, the field setup with one field is superior in complex topographic conditions. But, allocating an [Formula: see text]-value of 2 Gy to the spinal cord leads to critical high maximum doses in the spinal cord. The evaluation of dose profiles showed significant dose peaks at borders of the [Formula: see text]-gradient, especially in case of a single posterior field. CONCLUSION: Optimization with specific [Formula: see text]-values allows a more accurate view on dose distribution than previously. A field setup with one single posterior field achieves good results in case of difficult topographic conditions, but leads to high maximum doses to the spinal cord. So, field setups with multiple fields seem to be more adequate in case of LAPC, being surrounded by highly radiosensitive normal tissues.
Medical subject headings
- Heavy Ion Radiotherapy
- Pancreatic Neoplasms
- Radiotherapy Planning, Computer-Assisted