Reverse Total Shoulder Arthroplasty without Bone-Grafting for Severe Glenoid Bone Loss in Patients with Osteoarthritis and Intact Rotator Cuff.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 27807112.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Treating shoulders with osteoarthritis, an intact rotator cuff, and substantial glenoid bone loss is challenging. One option is reaming the glenoid flat and inserting a reverse prosthesis. This study reports the subjective, objective, and radiographic results of reverse total shoulder arthroplasty (RTSA) in this population. We retrospectively reviewed 42 consecutive patients (23 women; mean age, 71 years [range, 53 to 89 years]) with primary glenohumeral osteoarthritis, intact rotator cuffs, and Walch type-A2 (n = 19), B2 (n = 5), or C glenoids (n = 18) who had undergone a total of 42 RTSAs with glenoid reaming without bone-grafting between 2008 and 2013 (mean follow-up, 36 months [range, 24 to 66 months]). All patients were evaluated before and after surgery subjectively (using a visual analog scale for pain and 5 shoulder-specific outcome instruments), objectively (with goniometric examination of shoulder range of motion), and radiographically (to assess baseplate loosening and degree of scapular notching). One baseplate (2%) failed, requiring revision surgery. There were no other signs of baseplate loosening in any patient at the last follow-up. Preoperatively to postoperatively, pain improved significantly (p < 0.001), as did all patient-reported outcome measures and the following range-of-motion parameters (p ≤ 0.001): active abduction, active flexion, and active external rotation with the arm elevated 90°. Eight (19%) of the patients had notching. RTSA without bone-grafting and with medialization of the baseplate in patients with osteoarthritis and severe glenoid bone loss resulted in significant improvement in pain and function with reliable short-term implant survivorship and may be a good alternative to anatomical TSA. Longer follow-up is needed to determine the relative advantages and disadvantages. This was an "off-label" indication for this device. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Medical subject headings
- Arthroplasty, Replacement, Shoulder
- Osteoarthritis
- Scapula
- Shoulder Joint
Anatomy
- shoulder
- scapula