Evaluation of acute skin toxicity in breast radiotherapy with a new quantitative approach.

González Sanchis, Amparo; Brualla González, Luis; Sánchez Carazo, Jose Luis; Gordo Partearroyo, Jose Carlos; Esteve Martínez, Altea; Vicedo González, Aurora; López Torrecilla, Jose Luis · Radiother Oncol · 2017

prospective_cohort · Level II

Where this comes from

Abstract

Current criteria to evaluate acute radiodermatitis are highly subjective so quantification of physiological parameters is needed. We describe a non-invasive method of assessing skin microcirculation in breast cancer patients treated with hypofractionated radiotherapy and correlate them with the CTCAE scale. Prospective study of 63 patients where blood flow was measured with real-time laser Doppler flowmetry (LDF) at baseline, weekly, and 3-months post-radiotherapy. Skin toxicity was assessed with the microcirculation index (MCI), a novel index based on blood flow parameters obtained via LDF. MCI was positively correlated (R=0.647; p<0.001) with the dose. Changes in MCI from baseline to the end of radiotherapy and at 3-months post-radiotherapy were significant (p<0.001). All CTCAE groups experienced a significant increase in MCI values from baseline to end of radiotherapy (p<0.001 for CTCAE grades 0 and 1; and p=0.028 for the grade 2 group). Significant differences in MCI values were observed among CTCAE groups at the end of radiotherapy (p=0.016). LDF is an accurate and objective measure of changes in blood flow. The comparison with the CTCAE shows the limitations of this subjective way of classifying patients. LDF is the first step for future studies of radiodermatitis treatments and prevention.