Preemptive Aneurysm Sac Embolization for Thoracic Endovascular Aortic Repair With Inadequate Proximal Landing Zone.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 27847062.
- Also identified by DOI 10.1016/j.athoracsur.2015.12.038.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Thoracic endovascular aortic repair (TEVAR) offers a less invasive treatment for aortic arch aneurysms. Clinical challenges arise when there is inadequate proximal landing for zone 1 TEVAR, such that a median sternotomy with total aortic debranching is required before stent deployment. The chimney technique was reported as an alternative approach to stent the arch branches and avoid sternotomy, but it was still associated with considerable chance of a type IA endoleak. We report a case of aortic arch aneurysm with an inadequate proximal landing for zone 1 TEVAR that was treated with debranching of head and neck vessels followed by TEVAR and preemptive and targeted coil embolization of the arch aneurysmal sac. Postoperative computed tomography showed no significant endoleak, and the patient had an unremarkable recovery.
Medical subject headings
- Aortic Aneurysm, Thoracic
- Blood Vessel Prosthesis Implantation
- Embolization, Therapeutic
- Endovascular Procedures