Simulation of a Bead Placement Protocol for Follow-up of Thoracic Spinal Fusion Using Radiostereometric Analysis.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 27927462.
- Also identified by DOI 10.1016/j.jspd.2014.09.056.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Computer simulation to detect intervertebral motion enabling future follow-up of spinal fusions performed on patients with multilevel thoracic scoliosis. To propose a method using computer simulation to evaluate a radiostereometric analysis (RSA) marker placement protocol for visibility and redundancy and validate the performance of the developed RSA system in detecting intervertebral motion. Radiostereometric analysis is a stereo x-ray technique in which clusters of tantalum markers are implanted to label well-defined landmarks and measure the relative motion between rigid bodies. A model of the spine with the instrumentation and the RSA markers was developed. The vertebrae were aligned to mimic multilevel thoracic scoliosis after correction. The researchers performed virtual segment motion to validate the performance of the developed system. X-ray images were simulated and RSA was used to evaluate the proposed marker placement protocol and detect virtual motion. The authors performed a physical phantom study to evaluate marker visibility. All markers were located and matched between simulations and the condition numbers were well below the recommended value of 100. Based on computer simulation, average translational accuracy was 0.14, 0.01, and 0.24 mm along the x, y, and z axes, respectively, and average rotational accuracy was 0.23°, 0.12°, and 0.11° about the x, y, and z axes, respectively. The translational and rotational precision of the simulated RSA system was generally high. The physical phantom study agreed with the computer simulation and validated marker visibility. Computer simulation is a powerful tool that can be used to facilitate the development and refinement of an RSA system before its application in patients, particularly when the anatomy involved is complex. The proposed marker placement protocol yielded translational and rotational accuracy below the limits of clinical significance, which enables future follow-up of multilevel thoracic scoliosis with Lenke classification 1AN.
Anatomy
- thoracic spine