Semiquantitative Parameters in PSMA-Targeted PET Imaging with <sup>18</sup>F-DCFPyL: Variability in Normal-Organ Uptake.
Where this comes from
- Record sourced from PubMed, PMID 27932557.
- Also identified by DOI 10.2967/jnumed.116.179739 and PMC identifier 5450367.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
<sup>18</sup>F-DCFPyL is a small-molecule inhibitor of the prostate-specific membrane antigen that has shown promise for evaluation of primary and metastatic prostate cancer using PET. Measuring the variability in normal-organ uptake of <sup>18</sup>F-DCFPyL is necessary to understand its biodistribution, aid image interpretation, judge the reliability of scan quantification, and provide a basis for therapeutic monitoring. <b>Methods:</b> Sixty-five consecutive <sup>18</sup>F-DCFPyL PET/CT scans from 64 patients with a history of prostate cancer were analyzed. Volumes of interest were defined for the lacrimal glands, major salivary glands, liver, spleen, and both kidneys. The mean SUV normalized to body mass or to lean body mass (SUL) was calculated for each volume of interest. The average SUV across all scans, the SD, and the coefficient of variation (COV) for each organ were calculated. The same parameters were also derived for a 3-cm sphere drawn in the center of the right lobe of the liver. <b>Results:</b> The average SUV<sub>mean</sub> for all selected organs measured was 6.6 ± 1.8 for the right lacrimal gland, 6.4 ± 1.8 for the left lacrimal gland, 9.1 ± 2.0 for the right parotid gland, 9.0 ± 2.1 for the left parotid gland, 9.6 ± 2.3 for the right submandibular gland, 9.4 ± 2.2 for the left submandibular gland, 5.0 ± 0.7 for the whole liver, 5.1 ± 0.7 for a 3-cm sphere in the liver, 4.0 ± 1.5 for the spleen, 20.1 ± 4.6 for the right kidney, and 19.4 ± 4.5 for the left kidney. SUL<sub>mean</sub> was lower overall, although demonstrating similar trends. The COV of SUV<sub>mean</sub> and SUL<sub>mean</sub> was lower in the liver (13.8% and 14.5%, respectively) than in any other organ and was less than the comparable COV for <sup>18</sup>F-FDG PET. The COV of SUV<sub>mean</sub> and SUL<sub>mean</sub> in the 3-cm sphere in the liver was also low and similar to the variability in the whole liver (14.2% and 14.7%, respectively). <b>Conclusion:</b><sup>18</sup>F-DCFPyL uptake in normal liver demonstrates less variability than in other <sup>18</sup>F-DCFPyL-avid organs, and its variability is less than the reported variability of <sup>18</sup>F-FDG in liver. Variability was slightly less for SUV<sub>mean</sub> than for SUL<sub>mean</sub>, suggesting that SUV<sub>mean</sub> may be the preferable parameter for quantification of images obtained with <sup>18</sup>F-DCFPyL.
Medical subject headings
- Antigens, Surface
- Glutamate Carboxypeptidase II
- Lysine
- Pathology, Molecular
- Positron-Emission Tomography
- Prostatic Neoplasms
- Urea