Joint MR-PET Reconstruction Using a Multi-Channel Image Regularizer.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 28055827.
- Also identified by DOI 10.1109/TMI.2016.2564989 and PMC identifier 5218518.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
While current state of the art MR-PET scanners enable simultaneous MR and PET measurements, the acquired data sets are still usually reconstructed separately. We propose a new multi-modality reconstruction framework using second order Total Generalized Variation (TGV) as a dedicated multi-channel regularization functional that jointly reconstructs images from both modalities. In this way, information about the underlying anatomy is shared during the image reconstruction process while unique differences are preserved. Results from numerical simulations and in-vivo experiments using a range of accelerated MR acquisitions and different MR image contrasts demonstrate improved PET image quality, resolution, and quantitative accuracy.
Medical subject headings
- Magnetic Resonance Imaging
- Positron-Emission Tomography