We present a quantitative validation study to assess the accuracy of low-frequency conductivity imaging methods, based on a testing current measured using Current Density Imaging (CDI). We tested the proposed procedure to study the influence of tissue anisotropy on the accuracy of conductivity reconstruction methods, using a finite element model of anisotropic brain tissue. Simulations were carried out for three different levels of tissue anisotropy to compare the results obtained by our recently developed anisotropic conductivity method with those obtained by our well-established conductivity method that assumes isotropic conductivity. The validation results clearly show that the conductivity imaging method which takes into account tissue anisotropy yields significantly superior accuracy.
Medical subject headings
- Anisotropy