Arthroscopic fixation of the clavicle shaft fracture.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 28142348.
- Also identified by DOI 10.1177/2309499016684411.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This article describes an arthroscopic technique for the fixation of clavicle shaft fractures. A viewing portal is made 2 cm anterior to the fracture site, and a working portal is made 2 cm lateral to the fracture site. The guide wire for a 4.0-mm cannulated screw is inserted through the fracture site to the medial fracture fragment under arthroscopic guidance. Through the medial fragment, the guide wire is delivered through the skin anteriorly. The fracture is reduced, and then, the guide wire is drilled back across the fracture site to the lateral fracture fragment. After confirming the reduction under arthroscopy, the appropriately sized cannulated screw is inserted after reaming. This arthroscopic technique would be useful for the precise reduction and minimal invasive fixation of clavicle shaft fractures. Preliminary results are encouraging, and further studies with long-term follow-up are needed to determine the precise indications and limitations of the procedure.
Medical subject headings
- Arthroscopy
- Clavicle
- Fracture Fixation, Internal
- Fractures, Bone
Anatomy
- clavicle