Predicting the difficulty of operative vaginal delivery by ultrasound measurement of fetal head station.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 28153664.
- Also identified by DOI 10.1016/j.ajog.2017.01.007.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Clinical assessment of fetal head station is difficult and subjective; it is mandatory before attempting operative vaginal delivery. The principal objective of our study was to assess whether measurement of the perineum-to-skull ultrasound distance was predictive of a difficult operative vaginal delivery. Secondary objectives included evaluation of the interobserver reproducibility of perineum-to-skull ultrasound distance and comparison of this measurement and digital examination in predicting a difficult operative delivery. This was a prospective cohort study including all cases of operative vaginal deliveries in singleton pregnancies in cephalic presentation >34 weeks' gestation, from 2012 through 2015. All data were entered prospectively in a medical record system specially devised to meet the requirements of this study. Of the 659 patients in whom perineum-to-skull ultrasound distance was measured prior to operative vaginal delivery, 120 (18%) met the composite criterion for a difficult extraction. Perineum-to-skull ultrasound distance measurement of ≥40 mm was significantly associated with the occurrence of a difficult extraction based on the composite criterion, after adjustment for parity, presentation type, and fetal macrosomia (odds ratio, 2.38; 95% confidence interval, 1.51-3.74; P = .0002). The intraclass correlation coefficient between the perineum-to-skull ultrasound distance measured by the first operator and that measured by the second operator was 0.96 (95% confidence interval, 0.95-0.97; P < .0001). Based on the receiver operating characteristic curve analyses, perineum-to-skull ultrasound distance was a more accurate predictor of difficult operative delivery than digital vaginal examination (P = .036). Measurement of the perineum-fetal skull ultrasound distance is a reproducible and predictive index of the difficulty of instrumental extraction. Ultrasound is a useful supplementary tool to the usual clinical findings.
Medical subject headings
- Head
- Obstetrical Forceps
- Perineum
- Ultrasonography, Prenatal
- Vacuum Extraction, Obstetrical