Fetal QT Interval Estimation Using Sequential Hypothesis Testing.

Yu, Suhong; Van Veen, Barry D; Lutter, William J; Wakai, Ronald T · IEEE Trans Biomed Eng · 2017

other · Level V

Where this comes from

Abstract

<i>Objective</i>: Recent studies utilizing fetal magnetocardiography have demonstrated the efficacy of corrected QT interval (QTc) measurement for in utero diagnosis and prognosis of long QT syndrome, a leading cause of sudden death in early life. The objective of the study was to formulate and test a novel statistical estimation method to detect the end of the fetal T-wave and thereby improve the accuracy of fetal QT interval measurement. <i>Methods</i>: To detect the end of the T-wave, we apply a sequential composite hypothesis test to decide when the T-wave has returned to baseline. The method uses the generalized likelihood ratio test in conjunction with a low-rank spatiotemporal model that exploits the repetitive nature of cardiac signals. The unknown model parameters are determined using maximum likelihood estimation. <i>Results</i>: In realistic simulations, the detector was shown to be accurate to within 10 ms (95% prediction interval), even at noise-to-signal ratios as high as 6. When applied to real data from normal fetuses, the detector agreed well with measurements made by cardiologists ( 1.4 6.9 ms). <i>Conclusions</i>: The method was effective and practical. Detector performance was excellent despite the continual presence of strong maternal interference. <i>Significance</i>: This detector serves as a valuable adjunct to traditional measurement based on subjective assessment.<i>Objective</i>: Recent studies utilizing fetal magnetocardiography have demonstrated the efficacy of corrected QT interval (QTc) measurement for in utero diagnosis and prognosis of long QT syndrome, a leading cause of sudden death in early life. The objective of the study was to formulate and test a novel statistical estimation method to detect the end of the fetal T-wave and thereby improve the accuracy of fetal QT interval measurement. <i>Methods</i>: To detect the end of the T-wave, we apply a sequential composite hypothesis test to decide when the T-wave has returned to baseline. The method uses the generalized likelihood ratio test in conjunction with a low-rank spatiotemporal model that exploits the repetitive nature of cardiac signals. The unknown model parameters are determined using maximum likelihood estimation. <i>Results</i>: In realistic simulations, the detector was shown to be accurate to within 10 ms (95% prediction interval), even at noise-to-signal ratios as high as 6. When applied to real data from normal fetuses, the detector agreed well with measurements made by cardiologists ( 1.4 6.9 ms). <i>Conclusions</i>: The method was effective and practical. Detector performance was excellent despite the continual presence of strong maternal interference. <i>Significance</i>: This detector serves as a valuable adjunct to traditional measurement based on subjective assessment.

Medical subject headings