Clinical results of alumina medial pivot total knee arthroplasty at a minimum follow-up of 10years.

Nakamura, Suguru; Minoda, Yukihide; Nakagawa, Shigeru; Kadoya, Yoshinori; Takemura, Susumu; Kobayashi, Akio; Mizokawa, Shigekazu; Ohta, Yoichi et al. · Knee · 2017

retrospective_cohort · Level III

Where this comes from

Abstract

The medial pivot total knee prosthesis with alumina ceramic femoral components was introduced to reproduce physiological knee kinematics and reduce polyethylene wear. The five-year clinical outcomes of alumina medial pivot total knee arthroplasties (TKA) have previously been reported. The purpose of this study was to provide the longer-term clinical results at a minimum follow-up of 10years. The clinical results of 70 alumina medial pivot TKA in 51 consecutive patients, with a minimum follow-up period of 10years, were evaluated. Mean follow-up was 11.8years (range 10 to 13). Alumina medial pivot TKAs improved the patients' Knee Society knee scores, function scores, and postoperative ranges of motion compared with their pre-operative statuses (P<0.05 for each). Revision surgery was required in one knee due to a postoperative fracture of the tibial plateau after a fall that occurred two years postoperatively. Osteolysis and femoral component loosening was identified in one case after the initial five-year time point of analysis. The survival rate was 99.1% at 10years. This study demonstrated excellent clinical results for patients receiving the alumina medial pivot prosthesis at a minimum follow-up period of 10years.