Use of re-transfusion versus vacuum drains in primary total hip replacement.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 28224592.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Whilst the use of re-transfusion drains in primary knee arthroplasty has gained acceptance in reducing the requirement for donor blood products postoperatively, their use in total hip arthroplasty remains uncertain. Using two groups of 32 patients, a comparison was made between re-transfusion drains and vacuum drains in primary total hip arthroplasty in one centre and the requirement for postoperative donor blood. No statistically significant difference was found between the groups in terms of blood loss (p=0.51) or requirements for postoperative blood transfusion (p=0.12). The use of re-transfusion drains in primary total hip arthroplasty did not alter the rate of postoperative blood transfusion. (Hip International 2005; 15: 223-5).
Anatomy
- hip