Validity of the Instrumented Push and Release Test to Quantify Postural Responses in Persons With Multiple Sclerosis.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 28279660.
- Also identified by DOI 10.1016/j.apmr.2017.01.030 and PMC identifier 5558828.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Cross-sectional study. University medical center balance disorder laboratory. Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS.
Medical subject headings
- Actigraphy
- Multiple Sclerosis
- Postural Balance
Anatomy
- foot
- lumbar spine