Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 28523354.
- Also identified by DOI 10.1007/s00330-017-4791-2.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Endovascular aneurysm repair (EVAR) is considered the treatment of choice for abdominal aortic aneurysms with suitable anatomy. In order to improve radiation safety, European Directive (2013/59) requires member states to implement diagnostic reference levels (DRLs) in radio-diagnostic and interventional procedures. This study aimed to determine local DRLs for EVAR across five European centres and identify an interim European DRL, which currently remains unestablished. Retrospective data was collected for 180 standard EVARs performed between January 2014 and July 2015 from five specialist centres in Ireland (n=2) and Italy (n=3). Data capture included: air kerma-area product (P<sub>KA</sub>), total air kerma at the reference point (K<sub>a,r</sub>), fluoroscopic time (FT), number of acquisitions, frame rate of acquisition, type of acquisition, patient height, weight, and gender. The mean values for each site A, B, C, D, and E were: P<sub>KA</sub>s of 4343 ± 994 μGym<sup>2</sup>, 18,200 ± 2141 μGym<sup>2</sup>, 11,423 ± 1390 μGym<sup>2</sup>, 7796 ± 704 μGym<sup>2</sup>, 31,897 ± 5798 μGym<sup>2</sup>; FTs of 816 ± 92 s, 950 ± 150 s, 708 ± 70 s, 972 ± 61 s, 827 ± 118 s; and number of acquisitions of 6.72 ± 0.56, 10.38 ± 1.54, 4.74 ± 0.19, 5.64 ± 0.36, 7.28 ± 0.65, respectively. The overall pooled 75th percentile P<sub>KA</sub> was 15,849 μGym<sup>2</sup>. Local reference levels were identified. The pooled data has been used to establish an interim European DRL for EVAR procedures. • Abdominal endovascular aneurysm repair (EVAR) requires the use of ionising radiation. • EVAR is a minimally invasive procedure for the treatment of abdominal aortic aneurysms. • Diagnostic reference levels (DRLs) are used to monitor patient radiation exposure. • Radiation dose data was collected from five European centres for EVAR procedures. • Local DRLs have been determined and an interim European DRL is proposed.
Medical subject headings
- Aortic Aneurysm, Abdominal
- Endovascular Procedures
- Radiation Monitoring