Endovascular Fenestration for Distal Aortic Sealing After Frozen Elephant Trunk With Thoraflex.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 28528045.
- Also identified by DOI 10.1016/j.athoracsur.2016.12.039.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We describe a case of total arch replacement with frozen elephant trunk for chronic type B aortic dissecting aneurysm, which resulted in inadvertent landing of the frozen elephant trunk into the false lumen. A radiofrequency puncture system-assisted controlled endovascular fenestration of the dissection flap was performed at the upper abdominal aorta and subsequent thoracic endovascular stenting, successfully redirecting the blood flow from the false to the true lumen. Our case illustrated a possible way to seal distal reentry in chronic type B aortic dissection.
Medical subject headings
- Aortic Dissection
- Aortic Aneurysm, Thoracic
- Blood Vessel Prosthesis Implantation
- Endovascular Procedures
- Stents