An augmented iterative method for identifying a stress-free reference configuration in image-based biomechanical modeling.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 28549603.
- Also identified by DOI 10.1016/j.jbiomech.2017.04.021 and PMC identifier 8384073.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Continued advances in computational power and methods have enabled image-based biomechanical modeling to become an important tool in basic science, diagnostic and therapeutic medicine, and medical device design. One of the many challenges of this approach, however, is identification of a stress-free reference configuration based on in vivo images of loaded and often prestrained or residually stressed soft tissues and organs. Fortunately, iterative methods have been proposed to solve this inverse problem, among them Sellier's method. This method is particularly appealing because it is easy to implement, convergences reasonably fast, and can be coupled to nearly any finite element package. By means of several practical examples, however, we demonstrate that in its original formulation Sellier's method is not optimally fast and may not converge for problems with large deformations. Fortunately, we can also show that a simple, inexpensive augmentation of Sellier's method based on Aitken's delta-squared process can not only ensure convergence but also significantly accelerate the method.
Medical subject headings
- Models, Biological