The Variability of Translocator Protein Signal in Brain and Blood of Genotyped Healthy Humans Using In Vivo <sup>123</sup>I-CLINDE SPECT Imaging: A Test-Retest Study.

Feng, Ling; Jensen, Per; Thomsen, Gerda; Dyssegaard, Agnete; Svarer, Claus; Knudsen, Lars V; Møller, Kirsten; Thomsen, Carsten et al. · J Nucl Med · 2017

Where this comes from

Abstract

<sup>123</sup>I-CLINDE is a radiotracer developed for SPECT and targets the 18-kDa translocator protein (TSPO). TSPO is upregulated in glial cells and used as a measure of neuroinflammation in a variety of central nervous system diseases. The aim of this study was to examine the test-retest variability of <sup>123</sup>I-CLINDE binding in healthy subjects. <b>Methods:</b> SPECT scans were acquired over 90 min in 16 healthy controls (9 women, 8 mixed-affinity binders [MABs] and 8 high-affinity binders [HABs] twice with an interval of 35 ± 15 d). Arterial input functions were based on individual blood measurements in 8 subjects and a population-based approach in combination with individual whole-blood time-activity curves in the other 8 subjects. Seven brain volumes of interest were extracted and quantified by SUVs and by 2-tissue-compartment modeling for calculation of distribution volumes (<i>V</i><sub>T</sub>). Test-retest variability was measured by percentage difference (PD), the absolute PD, intraclass correlation coefficient (ICC), and coefficient of variation. <b>Results:</b> The absolute PD of brain SUV and the <i>V</i><sub>T</sub> had similar values. The ICC values were higher for <i>V</i><sub>T</sub>s than for brain SUVs, which were both moderate to high; however, lower ICC values were observed when calculated separately for HABs and MABs. Test-retest reproducibility was higher in subjects with immediate centrifugation of blood samples. The population-based method efficiently recovered data with delayed centrifugation. The <i>V</i><sub>T</sub> of a 49-y-old male HAB was 7.5 ± 1.4 mL/cm<sup>3</sup> compared with 4.6 ± 1.4 mL/cm<sup>3</sup> of a sex- and age-matched MAB. The SUVs of a 49-y-old male HAB and MAB were 1.03 ± 0.14 and 0.88 ± 0.15 g/mL, respectively. <b>Conclusion:</b> The test-retest reproducibility of <sup>123</sup>I-CLINDE is comparable or better than that reported for commonly used PET TSPO tracers. Because of the binding of <sup>123</sup>I-CLINDE to blood cells and peripheral tissues, SUV is not a sufficient surrogate of <i>V</i><sub>T</sub> from 2-tissue-compartment modeling. The population-adjusted method has the potential to reduce the complexity of blood analyses of TSPO tracers.

Medical subject headings