The diagnostic value of high-frequency power-based diffusion-weighted imaging in prediction of neuroepithelial tumour grading.

Chen, Zhiye; Zhou, Peng; Lv, Bin; Liu, Mengqi; Wang, Yan; Wang, Yulin; Lou, Xin; Gui, Qiuping et al. · Eur Radiol · 2017

retrospective_cohort · Level III

Where this comes from

Abstract

To retrospectively evaluate the diagnostic value of high-frequency power (HFP) compared with the minimum apparent diffusion coefficient (MinADC) in the prediction of neuroepithelial tumour grading. Diffusion-weighted imaging (DWI) data were acquired on 115 patients by a 3.0-T MRI system, which included b0 images and b1000 images over the whole brain in each patient. The HFP values and MinADC values were calculated by an in-house script written on the MATLAB platform. There was a significant difference among each group excluding grade I (G1) vs. grade II (G2) (P = 0.309) for HFP and among each group for MinADC. ROC analysis showed a higher discriminative accuracy between low-grade glioma (LGG) and high-grade glioma (HGG) for HFP with area under the curve (AUC) value 1 compared with that for MinADC with AUC 0.83 ± 0.04 and also demonstrated a higher discriminative ability among the G1-grade IV (G4) group for HFP compared with that for MinADC except G1 vs. G2. HFP could provide a simple and effective optimal tool for the prediction of neuroepithelial tumour grading based on diffusion-weighted images in routine clinical practice. • HFP shows positive correlation with neuroepithelial tumour grading. • HFP presents a good diagnostic efficacy for LGG and HGG. • HFP is helpful in the selection of brain tumour boundary.