Diagnostic performance of an automatic blood pressure measurement device, Microlife WatchBP Home A, for atrial fibrillation screening in a real-world primary care setting.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 28619766.
- Also identified by DOI 10.1136/bmjopen-2016-013685 and PMC identifier 5577883.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the diagnostic performance of a UK National Institute for Health and Care Excellence-recommended automatic oscillometric blood pressure (BP) measurement device incorporated with an atrial fibrillation (AF) detection algorithm (Microlife WatchBP Home A) for real-world AF screening in a primary healthcare setting. Primary healthcare setting in Hong Kong. This was a prospective AF screening study carried out between 1 September 2014 and 14 January 2015. The Microlife device was evaluated for AF detection and compared with a reference standard of lead-I ECG. Diagnostic performance of Microlife for AF detection. 5969 patients (mean age: 67.2±11.0 years; 53.9% female) were recruited. The mean CHA<sub>2</sub>DS<sub>2</sub>-VASc ( <b><u>C</u></b> : congestive heart failure [1 point]; <b><u>H</u></b> : hypertension [1 point]; <b><u>A<sub>2</sub></u></b> : age 65-74 years [1 point] and age ≥75 years [2 points]; <b><u>D</u></b> : diabetes mellitus [1 point]; <b><u>S</u></b> : prior stroke or transient ischemic attack [2 points]; <b><u>VA</u></b> : vascular disease [1 point]; and <b><u>Sc</u></b> : sex category [female] [1 point])score was 2.8±1.3. AF was diagnosed in 72 patients (1.21%) and confirmed by a 12-lead ECG. The Microlife device correctly identified AF in 58 patients and produced 79 false-positives. The corresponding sensitivity and specificity for AF detection were 80.6% (95% CI 69.5 to 88.9) and 98.7% (95% CI 98.3 to 98.9), respectively. Among patients with a false-positive by the Microlife device, 30.4% had sinus rhythm, 35.4% had sinus arrhythmia and 29.1% exhibited premature atrial complexes. With the low prevalence of AF in this population, the positive and negative predictive values of Microlife device for AF detection were 42.4% (95% CI 34.0 to 51.2) and 99.8% (95% CI 99.6 to 99.9), respectively. The overall diagnostic performance of Microlife device to detect AF as determined by area under the curves was 0.90 (95% CI 0.89 to 0.90). In the primary care setting, Microlife WatchBP Home was an effective means to screen for AF, with a reasonable sensitivity of 80.6% and a high negative predictive value of 99.8%, in addition to its routine function of BP measurement. In a younger patient population aged <65 years with a lower prevalence of AF, Microlife WatchBP Home A demonstrated a similar diagnostic accuracy.
Medical subject headings
- Atrial Fibrillation
- Blood Pressure Monitoring, Ambulatory
- Hypertension
- Primary Health Care
- Sphygmomanometers