Effective new membrane for preventing postthoracotomy pleural adhesion by surface water induction technology.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 28654705.
- Also identified by DOI 10.1371/journal.pone.0179815 and PMC identifier 5487045.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
After thoracic surgery, adhesions between the pleura can cause substantial complications. This study investigated the effectiveness of a novel membrane utilizing surface water induction technology to prevent adhesions. Eight beagles were divided into an experimental group (five males) and a control group (three females). The experimental group underwent thoracotomy on both the left and right sides of the chest. Both sides received the membrane, and the membrane on one side was glued to the pleura using tissue adhesive. The control group underwent thoracotomy only on the left side. Two weeks postoperatively, all dogs were sacrificed and adhesions were evaluated macroscopically and microscopically. Severe adhesion was seen between the parietal and visceral pleura in all control dogs, whereas the experimental group showed minor adhesion in only one dog on one side. Our novel anti-adhesive membrane appeared highly effective in preventing postthoracotomy pleural adhesions.
Medical subject headings
- Absorbable Implants
- Pleural Diseases
- Thoracotomy