Assessment of HIV Screening Tests for Use in Preexposure Prophylaxis Programs.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 28666370.
- Also identified by DOI 10.1093/infdis/jix297.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Preexposure prophylaxis programs involve frequent human immunodeficiency virus (HIV) testing. We evaluated the sensitivity of 2 antigen/antibody immunoassays (Architect and Bioplex), 2 antibody-based rapid tests (Vikia-HIV-1/2 and Autotest-VIH), and 1 antigen/antibody rapid test (Alere HIV Combo) for the diagnosis of HIV infection. Among the 31 HIV-1-infected participants in the ANRS-IPERGAY trial, HIV-1 RNA was detected alone in only 2. The sensitivities of the Architect and Bioplex assays were 83% (95% confidence interval [CI], 76%-99%) and 82% (95% CI, 63%-94%), respectively. The sensitivities of the Vikia, Autotest, and Alere tests were 54% (95% CI, 34%-72%), 50% (95% CI, 31%-69%), and 78% (95% CI, 58%-91%), respectively. Antigen/antibody tests should be preferred to avoid missing cases of acute HIV infection and to decrease the related risks of viral transmission and emergence of drug resistance.
Medical subject headings
- HIV Infections
- Immunoassay
- Pre-Exposure Prophylaxis