Bilirubin coating attenuates the inflammatory response to everolimus-coated stents.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 28691192.
- Also identified by DOI 10.1002/jbm.b.33955.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to evaluate the effects of bilirubin- and/or everolimus (EVL)-coated stents to prevent arterial neointimal hyperplasia and inflammation in vitro and in vivo. The stents were prepared by spray coating bare metal stents (BMS) with bilirubin and/or EVL. Study groups were divided into (1) BMS, (2) bilirubin-coated stents (BES), (3) commercialized stents (Synergy™; EES), and (4) bilirubin/EVL-coated stents (B-EES). The coating thickness and drug release rates were comparable to previous reports (i.e., <4 µm thickness and 50% drug release in 7 days). Smooth muscle cell migration was inhibited in both EVL-containing groups (20.5 ± 3.80% in EES and 18.4 ± 2.55% in B-EES) compared to the non-EVL-containing groups (78.0 ± 6.41% in BMS and 76.1 ± 4.88% in BES) (n = 10, p < 0.05). Stents were randomly implanted to 40 coronary arteries in 20 pigs and subjected to various analyses after 4 weeks of implantation. As results, the inflammation score was dramatically increased in the EES group (2.1 ± 0.42) compared to that of the other groups (1.5 ± 0.55, 1.3 ± 0.23, and 1.5 ± 0.27 for BMS, BES, and B-EES, respectively, n = 10, p < 0.05). Immunofluorescence analysis revealed that inflammation was prevented in the bilirubin-containing groups (BES and B-EES). However, the percent area of restenosis was decreased in the EVL-containing groups (20.5 ± 4.11% for EES and 18.4 ± 3.61% for B-EES) compared to the non-EVL-containing groups (32.3 ± 6.41% for BMS and 29.6 ± 5.95% for BES, n = 10, p < 0.05). The percent areas of restenosis determined by histopathology, optical coherence tomography, and micro-computed tomography were consistent. In addition, the stent was barely covered in the EES and B-EES groups at 4 weeks postimplantation. These dual drug-coated stents may be especially beneficial to patients who have an increased risk of inflammation. These stents have great potential for use in cardiovascular applications. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1486-1495, 2018.
Medical subject headings
- Bilirubin
- Coronary Vessels
- Drug-Eluting Stents
- Graft Occlusion, Vascular
- Muscle, Smooth, Vascular
- Myocytes, Smooth Muscle