Fixation of Ultrasmall Proximal Pole Scaphoid Fractures Using Bioabsorbable Osteochondral Fixation Nails.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 28709792.
- Also identified by DOI 10.1016/j.jhsa.2017.06.011.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Surgical treatment of ultrasmall proximal pole scaphoid fractures poses a number of challenges. The fragment may be too small to fix with conventional headless screw fixation owing to the high risk of fragmentation upon insertion. However, excision of the fragment risks compromising the scapholunate ligament complex and also exposes the radioscaphoid joint to potential degenerative changes. Under these circumstances, we describe the use of bioabsorbable osteochondral fixation nails that allows stable low-profile fixation while minimizing the risk of fracturing the proximal pole.
Medical subject headings
- Absorbable Implants
- Bone Nails
- Fracture Fixation, Internal
- Fractures, Bone
- Scaphoid Bone