Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound: Volume Versus Diameter.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 28765014.
- Also identified by DOI 10.1016/j.ejvs.2017.06.016.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. In total, 179 patients with small infrarenal AAAs (diameter 30-55 mm) were enrolled consecutively. At enrolment and at 12 month follow-up, maximum diameter, using dual plane technique, and three dimensional volume were measured. Based on a previous accuracy study, significant change in diameter and volume were defined as an increase exceeding the known range of variability (ROV) of each US technique; ±3.7 mm and ±8.8 mL, respectively. Post-hoc Kaplan-Meier analysis was performed to estimate time to conversion to treatment after the conclusion of the follow-up period between two groups. In total, 125 patients (70%) had an unchanged diameter during follow-up. In this group, 50 patients (40%) had an increasing aortic volume. Forty-five (83%) of the 54 patients with an increasing aortic diameter showed a corresponding volume increase. During a median follow-up of 367 days (364-380 days), a mean increase in diameter of 2.7 mm (±2.6 mm) and a mean increase in volume of 11.6 mL (±9.9 mL) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. In this cohort of small AAAs, 40% of patients with a stable diameter had an increasing volume at 12 month follow-up. From this perspective, 3D-US could have a future supplemental role in AAA surveillance programmes.
Medical subject headings
- Aortic Aneurysm, Abdominal
- Imaging, Three-Dimensional
- Ultrasonography