Comparison of <sup>18</sup>F-FET PET and perfusion-weighted MRI for glioma grading: a hybrid PET/MR study.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 28831534.
- Also identified by DOI 10.1007/s00259-017-3812-3.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Both perfusion-weighted MR imaging (PWI) and O-(2-<sup>18</sup>F-fluoroethyl)-L-tyrosine PET (<sup>18</sup>F-FET) provide grading information in cerebral gliomas. The aim of this study was to compare the diagnostic value of <sup>18</sup>F-FET PET and PWI for tumor grading in a series of patients with newly diagnosed, untreated gliomas using an integrated PET/MR scanner. Seventy-two patients with untreated gliomas [22 low-grade gliomas (LGG), and 50 high-grade gliomas (HGG)] were investigated with <sup>18</sup>F-FET PET and PWI using a hybrid PET/MR scanner. After visual inspection of PET and PWI maps (rCBV, rCBF, MTT), volumes of interest (VOIs) with a diameter of 16 mm were centered upon the maximum of abnormality in the tumor area in each modality and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios (TBR<sub>mean</sub>, TBR<sub>max</sub>) were calculated. In addition, Time-to-Peak (TTP) and slopes of time-activity curves were calculated for <sup>18</sup>F-FET PET. Diagnostic accuracies of <sup>18</sup>F-FET PET and PWI for differentiating low-grade glioma (LGG) from high-grade glioma (HGG) were evaluated by receiver operating characteristic analyses (area under the curve; AUC). The diagnostic accuracy of <sup>18</sup>F-FET PET and PWI to discriminate LGG from HGG was similar with highest AUC values for TBR<sub>mean</sub> and TBR<sub>max</sub> of <sup>18</sup>F-FET PET uptake (0.80, 0.83) and for TBR<sub>mean</sub> and TBR<sub>max</sub> of rCBV (0.80, 0.81). In case of increased signal in the tumor area with both methods (n = 32), local hot-spots were incongruent in 25 patients (78%) with a mean distance of 10.6 ± 9.5 mm. Dynamic FET PET and combination of different parameters did not further improve diagnostic accuracy. Both <sup>18</sup>F-FET PET and PWI discriminate LGG from HGG with similar diagnostic performance. Regional abnormalities in the tumor area are usually not congruent indicating that tumor grading by <sup>18</sup>F-FET PET and PWI is based on different pathophysiological phenomena.
Medical subject headings
- Glioma
- Magnetic Resonance Imaging
- Multimodal Imaging
- Perfusion Imaging
- Positron-Emission Tomography
- Tyrosine