Predicting Fluid Responsiveness in Critically Ill Patients by Using Combined End-Expiratory and End-Inspiratory Occlusions With Echocardiography.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 28857907.
- Also identified by DOI 10.1097/CCM.0000000000002704.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
First, we aimed at assessing whether fluid responsiveness is predicted by the effects of an end-expiratory occlusion on the velocity-time integral of the left ventricular outflow tract. Second, we investigated whether adding the effects of an end-inspiratory occlusion and of an end-expiratory occlusion on velocity-time integral can predict fluid responsiveness with similar reliability than end-expiratory occlusion alone but with a higher threshold, which might be more compatible with the precision of echocardiography. Diagnostic study. Medical ICU. Thirty mechanically ventilated patients in whom fluid administration was planned. A 15-second end-expiratory occlusion and end-inspiratory occlusion, separated by 1 minute, followed by a 500-mL saline administration. Pulse contour analysis-derived cardiac index and velocity-time integral were measured during the last 5 seconds of 15-second end-inspiratory occlusion and end-expiratory occlusion and after fluid administration. End-expiratory occlusion increased velocity-time integral more in responders than in nonresponders to fluid administration (11% ± 5% vs 3% ± 1%, respectively; p < 0.0001), and end-inspiratory occlusion decreased velocity-time integral more in responders than in nonresponders (12% ± 5% vs 5% ± 2%, respectively; p = 0.0002). When adding the absolute values of changes in velocity-time integral observed during both occlusions, velocity-time integral changed by 23% ± 9% in responders and by 8% ± 3% in nonresponders. Fluid responsiveness was predicted by the end-expiratory occlusion-induced change in velocity-time integral with an area under the receiver operating characteristic curve of 0.938 (0.785-0.989) and a threshold value of 5%. Fluid responsiveness was predicted by the sum of absolute values of changes in velocity-time integral during both occlusions with a similar reliability (area under the receiver operating characteristic curve = 0.973 [0.838-1.000]) but with a threshold of 13%. Both sensitivity and specificity were 93% (68-100%). If consecutive end-inspiratory occlusion and end-expiratory occlusion change velocity-time integral is greater than or equal to 13% in total, fluid responsiveness is accurately predicted. This threshold is more compatible with the precision of echocardiography than that obtained by end-expiratory occlusion alone.
Medical subject headings
- Echocardiography
- Exhalation
- Fluid Therapy
- Inhalation
- Respiration, Artificial